EGR 224/RC Lab

From PrattWiki
Revision as of 02:51, 28 February 2012 by DukeEgr93 (talk | contribs)
Jump to navigation Jump to search

The following page provides some supplemental information for the RC Circuits and Filtering lab for EGR 119L. It has been updated for Spring, 2012.

Clarifications

  • None yet

Element Values

  • Resistances:
    • 1, 2, 3, 13, 14, 15: 1 k\(\Omega\)
    • 4, 5, 6, 16, 17, 18: 2.2 k\(\Omega\)
    • 7, 8, 9, 19, 20, 21: 4.7 k\(\Omega\)
    • 10, 11: 10 k\(\Omega\)
    • 12: 15 k\(\Omega\)
  • Capacitances
    • 7, 10, 12, 19: 1 \(\mu\)F
    • 4, 8, 11, 16, 20: 2.2 \(\mu\)F
    • 1, 5, 9, 13, 17, 21: 4.7 \(\mu\)F
    • 2, 6, 14, 18: 10 \(\mu\)F
    • 3, 15: 22 \(\mu\)F

Links

Wiring Images

Click on the pictures above to make them larger.