CB-68LP Pinout
Jump to navigation
Jump to search
The following charts lists the different connections as laid out on the National Instruments CB-68LP connection block when used in conjunction with the National Instruments PCI 6014e Data Aquisition Card. The list under the table describes the most commonly used channels.
68 ACH0 | 61 ACH12 | 15 DGND | 08 +5V | 01 FREQ_OUT |
34 ACH8 | 27 AIGND | 49 DIO2 | 42 GPCTR1_SRC | 35 DGND |
67 AIGND | 60 ACH5 | 16 DIO6 | 9 DGND | 2 GPCTR0_OUT |
33 ACH1 | 26 ACH13 | 50 DGND | 43 CONVERT | 36 DGND |
66 ACH 9 | 59 AIGND | 17 DIO1 | 10 TRIG2 | 3 GPCTR0_GATE |
32 AIGND | 25 ACH6 | 51 DIO5 | 44 DGND | 37 GPCTR0_SRC |
65 ACH2 | 58 ACH14 | 18 DGND | 11 TRIG1 | 4 DGND |
31 ACH10 | 24 AIGND | 52 DIO0 | 45 EXTSTROBE | 38 STARTSCAN |
64 AIGND | 57 ACH7 | 19 DIO4 | 12 DGND | 5 WFTRIG |
30 ACH3 | 23 ACH15 | 53 DGND | 46 SCANCLK | 39 DGND |
63 ACH11 | 56 AIGND | 20 RESERVED | 13 DGND | 6 UPDATE |
29 AIGND | 22 DAC0OUT | 54 AOGND | 47 DIO3 | 40 GPCTR1_OUT |
62 AISENSE | 55 AOGND | NA NA | 14 +5V | 7 DGND |
28 ACH4 | 21 DAC1OUT | NA NA | 48 DIO7 | 41 GPCTR1_GATE |
The most commonly used channels are:
- ACH# - analog input channel number #
- DAC#OUT - analog output channel number #
- DIO# - digital input/output (I/O) channel number #
- AIGND - ground (0 V) for the analog input channels
- AOGND - ground (0 V) for the analog output channels