EGR 224/Active Filter

From PrattWiki
Revision as of 13:37, 27 September 2017 by DukeEgr93 (talk | contribs)
Jump to navigation Jump to search

The following page provides some supplemental information for the Active Filters lab for EGR 224L. It has been updated to Spring, 2017.

Script from 7.4.2

clear
load DukeFightSong
%% Filter constants
R = 10000;   C = 50e-9;

%% Experimental Transfer Function
[EstH, EstF] = tfestimate(SoundIn, SoundOut, [], [], [], samplerate);
EstMag = abs(EstH);
EstOmega = EstF*2*pi;
%% Analytical Transfer Function
s = tf([1 0], [1]);
H = 1 / (1 + s * R * C);
[HMag, HPhase, HOmega] = bode(H, {1, max(EstOmega)});
HMag = squeeze(HMag);
%% Make plot
figure(1); clf
semilogx(EstOmega, 20*log10(EstMag), 'b-')
hold on
semilogx(HOmega, 20*log10(HMag), 'r-')
hold off
xlabel('\omega, rad/s'); ylabel('|H|, dB')
legend('Estimates', 'Theoretical', 'location', 'best')