EGR 224/RC Lab
Jump to navigation
Jump to search
The following page provides some supplemental information for the RC Circuits and Filtering lab for EGR 224L. It has been updated for Spring, 2013.
Clarifications
- None yet
Element Values
- Resistances:
- 1, 2, 3, 13, 14, 15: 1 k\(\Omega\)
- 4, 5, 6, 16, 17, 18: 2.2 k\(\Omega\)
- 7, 8, 9, 19, 20, 21: 4.7 k\(\Omega\)
- 10, 11, 22, 23: 10 k\(\Omega\)
- 12, 24: 15 k\(\Omega\)
- Capacitances
- 7, 10, 12, 19, 22, 24: 1 \(\mu\)F
- 4, 8, 11, 16, 20, 23: 2.2 \(\mu\)F
- 1, 5, 9, 13, 17, 21: 4.7 \(\mu\)F
- 2, 6, 14, 18: 10 \(\mu\)F
- 3, 15: 22 \(\mu\)F
Links
- The MATLAB:Transfer Functions page should be very helpful here
- The files for this assigned can be downloaded from here
Wiring Images
Closeup of the CB-68LP
Click on the pictures above to make them larger.