The following charts lists the different connections as laid out on the National Instruments CB-68LP connection block when used in conjunction with the National Instruments PCI 6014e Data Aquisition Card. The list under the table describes the most commonly used channels.

68 ACH0 61 ACH12 15 DGND 08 +5V 01 FREQ_OUT
34 ACH8 27 AIGND 49 DIO2 42 GPCTR1_SRC 35 DGND
67 AIGND 60 ACH5 16 DIO6 9 DGND 2 GPCTR0_OUT
33 ACH1 26 ACH13 50 DGND 43 CONVERT 36 DGND
66 ACH 9 59 AIGND 17 DIO1 10 TRIG2 3 GPCTR0_GATE
32 AIGND 25 ACH6 51 DIO5 44 DGND 37 GPCTR0_SRC
65 ACH2 58 ACH14 18 DGND 11 TRIG1 4 DGND
31 ACH10 24 AIGND 52 DIO0 45 EXTSTROBE 38 STARTSCAN
64 AIGND 57 ACH7 19 DIO4 12 DGND 5 WFTRIG
30 ACH3 23 ACH15 53 DGND 46 SCANCLK 39 DGND
63 ACH11 56 AIGND 20 RESERVED 13 DGND 6 UPDATE
29 AIGND 22 DAC0OUT 54 AOGND 47 DIO3 40 GPCTR1_OUT
62 AISENSE 55 AOGND NA NA 14 +5V 7 DGND
28 ACH4 21 DAC1OUT NA NA 48 DIO7 41 GPCTR1_GATE

The most commonly used channels are:

  • ACH# - analog input channel number #
  • DAC#OUT - analog output channel number #
  • DIO# - digital input/output (I/O) channel number #
  • AIGND - ground (0 V) for the analog input channels
  • AOGND - ground (0 V) for the analog output channels