EGR 224/RC Lab

From PrattWiki
Revision as of 15:12, 19 March 2019 by DukeEgr93 (talk | contribs)
Jump to navigation Jump to search

The following page provides some supplemental information for the RC Circuits and Filtering lab for EGR 224L. It has been updated for Spring, 2019.

Clarifications

  • If any of your figures looks wrong, it probably is! Be sure to have a TA check your figures so that you leave the lab with a valid data set.
  • Use MATLAB on the PC to do the data acquisition
  • For newer versions of MATLAB (2015 and after), the proper way to get out of a "keyboard" environment is to type the word "dbcont" and hit enter; the word "return" no longer works for that
  • For Maple, when you put in the sinusoid at 60 rad/s, Maple may try to be "helpful" and use double angle formula to come up with a result that is a complete mess; try a frequency of 60.01 rad/s instead. It's just about the same speed and Maple won't be...helpful...
  • The experimental phase values should track well at low frequencies but may fluctuate a bit at higher frequencies due to inaccuracies in determining peaks.

Element Values

  • Resistances:
    • 1, 9, 17: 2.2 k\(\Omega\)
    • 2, 3, 10, 11, 18, 19: 4.7 k\(\Omega\)
    • 4, 5, 12, 13, 20, 21: 10 k\(\Omega\)
    • 6, 14, 16, 22: 15 k\(\Omega\)
    • 7, 8, 15, 23, 24: 22 k\(\Omega\)
  • Capacitances
    • 7, 15, 23: 2.2 \(\mu\)F
    • 4, 6, 8, 12, 14, 16, 20, 22, 24: 4.7 \(\mu\)F
    • 2, 5, 10, 13, 18, 21: 10 \(\mu\)F
    • 1, 3, 9, 11, 17, 19: 22 \(\mu\)F

Links

Wiring Images

Click on the pictures above to make them larger.