Difference between revisions of "EGR 224/RC Lab"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
− | The following page provides some supplemental information for the '''RC Circuits and Filtering''' lab for [[EGR 119|EGR 119L]]. It has been updated | + | The following page provides some supplemental information for the '''RC Circuits and Filtering''' lab for [[EGR 119|EGR 119L]]. It has been updated for Spring, 2012. |
== Clarifications == | == Clarifications == | ||
− | * | + | * None yet |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
== Element Values == | == Element Values == |
Revision as of 23:59, 26 February 2012
The following page provides some supplemental information for the RC Circuits and Filtering lab for EGR 119L. It has been updated for Spring, 2012.
Clarifications
- None yet
Element Values
- Resistances:
- 1, 2, 3, 13, 14, 15: 1 k\(\Omega\)
- 4, 5, 6: 2.2 k\(\Omega\)
- 7, 8, 9: 4.7 k\(\Omega\)
- 10, 11: 10 k\(\Omega\)
- 12: 15 k\(\Omega\)
- Capacitances
- 7, 10, 12: 1 \(\mu\)F
- 4, 8, 11: 2.2 \(\mu\)F
- 1, 5, 9, 13: 4.7 \(\mu\)F
- 2, 6, 14: 10 \(\mu\)F
- 3, 15: 22 \(\mu\)F
Links
- The MATLAB:Transfer Functions page should be very helpful here
- The files for this assigned can be downloaded from here
Wiring Images
Click on the pictures at right to make them larger.